PMAC Product Guide Ix31 Motor x PID Derivative Gain Range: - 8,388,608 .. 8,388,607 Default: 1280 Units: (Ix30*Ix09)/2 26 DAC bits/(Counts/cycle) This term subtracts an amount from the control output proportional to the measured velocity of motor x. It acts effectively as an electronic damper. The higher Ix31 is, the heavier the damping effect is. If the motor is driving a properly tuned tachometer-loop (velocity) amplifier, the amplifier will provide sufficient damping, and Ix31 should be set to zero.
If the motor is driving a current-loop (torque) amplifier, or if PMAC is commutating the motor, the amplifier will provide no damping, and Ix31 must be greater than zero to provide damping for stability. On a typical system with a current-loop amplifier and PMAC's default servo update time (~440 µ sec), an Ix31 value of 2000 to 3000 will provide a critically damped step response. If the servo update time is changed, Ix31 must be changed proportionately in the opposite direction to keep the same damping effect. For instance, if the servo update time is cut in half, from 440 µ sec to 220 µ sec, Ix31 must be doubled to keep the same effect.
Usually, this parameter is set initially using the Tuning utility in the PMAC Executive Program. It may be changed on the fly at any time to create types of adaptive control. Ix32 Motor x PID Velocity Feedforward Gain Range: 0 .. 8,388,607 Default: 1280 Units: (Ix30*Ix08)/2 26 DAC bits/(counts/cycle) This term adds an amount to the control output proportional to the desired velocity of motor x. It is intended to reduce tracking error due to the damping introduced by Ix31, analog tachometer feedback, or physical damping effects. If the motor is driving a current-loop (torque) amplifier, Ix32 will usually be equal to (or slightly greater than) Ix31 to minimize tracking error.
If the motor is driving a tachometer-loop (velocity) amplifier, typically Ix32 will be substantially greater than Ix31 to minimize tracking error. If the servo update time is changed, Ix32 must be changed proportionately in the opposite direction to keep the same effect. For instance, if the servo update time is cut in half, from 440 µ sec to 220 µ sec, Ix32 must be doubled to keep the same effect. Usually, this parameter is set initially using the Tuning utility in the PMAC Executive Program. It may be changed on the fly at any time to create types of adaptive control. Ix33 Motor x PID Integral Gain Range: 0 .. 8,388,607 Default: 0 Units:
(Ix30*Ix08)/2 42 DAC bits/(counts*cycles) This term adds an amount to the control output proportional to the time integral of the position error for motor x. The magnitude of this integrated error is limited by Ix63. With Ix63 at a value of zero, the contribution of the integrator to the output is zero, regardless of the value of Ix33. No further errors are added to the integrator if the output saturates (if output equals Ix69), and, if Ix34=1, when a move is being commanded (when desired velocity is not zero). In both of these cases, the contribution of the integrator to the output remains constant. I-Variables 119