PMAC Product Guide If the source of the time base is the % command register, then Ix94 defines the rate at which the % (actual time base) value will slew to a newly commanded value. If the rate is too high and the % value is changed while axes in the coordinate system are moving, there will be a virtual step change in velocity. For these types of applications, Ix94 is set relatively low (often 1000 to 5000) to provide smooth changes. The default Ix94 value of 1644 when used on a card set up with the default servo cycle time of 442 µ sec, provides a transition time between %0 and %100 of one second.
If there is a hardware source (as defined by Ix93), the commanded time-base value changes every servo cycle and the rate of change of the commanded value is limited typically by hardware considerations (e.g. inertia). In this case, Ix94 effectively defines the maximum rate at which the % value can slew to the new hardware-determined value and the actual rate of change is determined by the hardware. To keep synchronous to a hardware input frequency, as in a position-lock cam, Ix94 should be set high enough so that the limit is never activated. However, following motion can be smoothed significantly with a lower limit if total synchronicity is not required.
Ix95 Coordinate System x Feed Hold Deceleration Rate Range: 0 .. 8,388,607 Default: 1644 Units: 2 -23 msec/servo cycle This parameter controls the rate at which the axes of the coordinate system stop if a feed hold command ( H ) is given, and the rate at which they start up again on a succeeding run command ( R or S ). A feed hold command is equivalent to a %0 command except that it uses Ix95 for its slew rate instead of Ix94. Having separate slew parameters for normal time-base control and for feed hold commands allows both responsive ongoing time-base control (Ix94 relatively high) and well-controlled holds (Ix95 relatively low).
The default Ix95 value of 1644, when used on a card set up with the default servo cycle time of 442 µ sec, provides a transition time between %100 and %0 (feed hold) of one second. Ix96 Coordinate System x Circle Error Limit Range: Positive floating point Default: 0 (function disabled) Units: User length units In a circular arc move, a move distance that is more than twice the specified radius will cause a computation error because a proper path cannot be found. Sometimes, due to round-off errors, a distance slightly larger than twice the radius is given (for a half-circle move that this will not create an error condition.
This parameter is used to set an error limit on the amount so that the move distance is greater than twice the radius. If the move distance is greater than 2R, but by less than this limit, the move is done in a spiral fashion to the endpoint, and no error condition is generated. If the distance error is greater than this limit, a run-time error will be generated and the program will stop. If this variable is set to 0, the error generation is disabled and any move distance greater than 2R is done in a spiral fashion to the endpoint. Example:
Given the program segment INC CIRCLE1 F2 X7.072 Y7.072 R5 Technically, no circular arc path can be found because the distance is SQRT(7.072 2 +7.072 2 ) = 10.003, which is greater than twice the radius of 5. However, as long as Ix96 is greater than 0.003, PMAC will create a near-circular path to the end point. I-Variables 125