PMAC Product Guide Ix90 Coordinate System x Feedrate Time Units Range: Positive floating point Default: 1000.0 (velocity time units are seconds) Units: msec This parameter defines the time units used in commanded velocities (feedrates) in motion programs executed by coordinate system x. Velocity units are comprised of length units divided by time units. The length units are determined in the axis definition statements for the coordinate system. Ix90 sets the time units. Ix90 itself has units of milliseconds, so if Ix90 is 60,000, the time units are 60,000 milliseconds, or minutes. The default value of Ix90 is 1000 msec, specifying velocity time units of seconds.
This affects two types of motion program values: F values (feedrate) for LINEAR - and CIRCLE -mode moves; and the velocities in the actual move commands for PVT -mode moves. Example: If position units have been set as centimeters by the axis definition statements and feedrate values should be specified in cm/sec, this parameter would be set to 1000.0 (time units = sec). If position units have been set as degrees by the axis definition statements feedrate values should be specified in deg/min, this parameter would be set to 60,000.0 (time units = minutes).
If a spindle is rotating at 4800 rpm, with a linear axis specified in inches linear speed should be specified in inches per spindle revolution, Ix90 would be set to 12.5 ([1 min/4800 rev] * [60,000 msec/ min] = 12.5 msec/rev). Ix91 Coordinate System x Default Working Program Number Range: 0 .. 32,767 Default: 0 Units: Motion Program Numbers This parameter tells PMAC which motion program to run in this coordinate system when commanded to run from the control-panel input (START/ or STEP/ line taken low). It performs the same function for a hardware run command as the B command does for a software run command ( R ). It is intended primarily for stand-alone PMAC applications.
The first use of a B command from a host computer for this coordinate system overrides this parameter. Ix92 Coordinate System x Move Blend Disable Range: 0 .. 1 Default: 0 Units: none If this parameter is set to 0, programmed blended moves ( LINEAR , SPLINE , and CIRCLE -mode) are blended together with no intervening stop. Upcoming moves are calculated during the current moves. If this parameter is set to 1, there is a brief stop in between each programmed move (it effectively adds a DWELL 0 command) during which the next move is calculated. The calculation time for the next move is determined by I11.
This parameter is acted upon only when the R or S command is given to start program execution. To change the mode of operation while the program is running, the continuous motion request coordinate system status bit (bit 4 of X:$0818 etc.) must be changed. The polarity of this bit is opposite that of Ix92. Ix94 Coordinate System x Time Base Slew Rate (and Limit) Range: 0 .. 8,388,607 Default: 1644 Units: 2 -23 msec/ servo cycle This parameter controls the rate of change of the coordinate system’s time base. It effectively works in two slightly different ways depending on the source of the time base information. 124 I-Variables