PMAC Product Guide Make sure that the specified acceleration time (Ix87 or 2*Ix88) is greater than zero, even if planning to rely on the maximum acceleration rate parameters. A specified acceleration time of zero will cause a divide-by-zero error. The minimum specified time should be Ix87=1, Ix88=0. Ix88 Coordinate System x Default Program S-Curve Time Range: 0 .. 8,388,607 Default: 50 Units: msec This parameter set the default time in each half of the S in S-curve acceleration for programmed blended LINEAR and CIRCLE mode moves in coordinate system x. It does not affect SPLINE , PVT , or RAPID mode moves. The first use of a TS statement in a program overrides this value.
Even though this parameter makes it possible not to specify acceleration time in the motion program, use TA in the program and not rely on this parameter, unless keeping to a syntax standard that does not support this (e.g. RS-274 G-Codes). Specifying acceleration time in the program along with speed and move modes makes it much easier for later debugging. If Ix88 is zero, the acceleration is constant throughout the Ix87 time and the velocity profile is trapezoidal.
If Ix88 is greater than zero, the acceleration will start at zero and linearly increase through Ix88 time, then stay constant (for time TC) until Ix87-Ix88 time, and linearly decrease to zero at Ix87 time (that is Ix87=2*Ix88 - TC). If Ix88 is equal to Ix87/2, the entire acceleration will be spec in S-curve form (Ix88 values greater than Ix87/2 override the Ix87 value; total acceleration time will be 2*Ix88). The acceleration time will be extended automatically when any motor in the coordinate system is asked to exceed its maximum acceleration rate (Ix17) for a programmed LINEAR mode move with I13=0 (no move segmentation).
Make sure the specified acceleration time (TA or 2*TS) is greater than zero, even if planning to rely on the maximum acceleration rate parameters (Ix17). A specified acceleration time of zero will cause a divide-by-zero error. The minimum specified time should be TA1 TS0 . Ix89 Coordinate System x Default Program Feedrate/Move Time Range: Positive floating point Default: 1000.0 Units: (user position units)/(feedrate time units) for feedrate msec for move time This parameter sets the default feedrate (commanded speed) for programmed LINEAR and CIRCLE mode moves in coordinate system x. The first use of an F or TM statement in a motion program overrides this value.
The velocity units are defined by the position and time units, as defined by axis definition statements and Ix90. After power-up/reset, the coordinate system is in feedrate mode, not move time mode. Do not rely on this parameter but declare the feedrate in the program. This will keep the move parameters with the move commands lessening the chances of future errors and making debugging easier. When polled, Ix89 will report the value from the most recently executed F or TM command in that coordinate system. I-Variables 123