omron — Ix87 Coordinate System x Default Program Acceleration Time

PMAC Product Guide For non-PMAC-commutated motors, a J/ (jog stop) or $ (motor reset) command (for the motor), an A (abort) command (for all motors in the coordinate system), or a (abort all) command (for all PMAC motors) must be given to put the motor in closed-loop servo control. If Ix80 is 1 or 3, the motor is enabled automatically at power-up/reset and put in closed-loop servo control at zero commanded velocity. If a phasing search is required, it is done automatically during the power- up/reset cycle.

If Ix80 is 0 or 1 and a phasing search is required, PMAC will use the two-guess phasing search method, which is very quick and requires little movement, but is not as reliable in the presence of significant external loads such as friction and gravity. If Ix80 is 2 or 3 and a phasing search is required, PMAC will use the stepper-motor phasing search method, which is takes more time and causes more movement, but is more reliable in the presence of significant external loads. Warning: An unreliable phasing search method can lead to a runaway condition. Test your phasing search method carefully to make sure it works properly under all conceivable conditions.

Make sure your Ix11 fatal following error limit is active and as tight as possible so the motor will be killed quickly in the event of a serious phasing search error. If Ix80 is 1 or 3, and the motor is disabled right after the power-up/reset cycle, the motor is either being killed by an automatic PMAC safety feature (fatal following error, amplifier fault, or phasing search error) or by a kill command from a PLC program. Coordinate System I-Variables Ix87 Coordinate System x Default Program Acceleration Time Range: 0 .. 8,388,607 Default: 0 (so Ix88 controls) Units:

msec This parameter sets the default time for commanded acceleration for programmed blended LINEAR and CIRCLE mode moves in coordinate system x. It also provides the default segment time for SPLINE mode moves. The first use of a TA statement in a program overrides this value. Even though this parameter makes it possible not to specify acceleration time in the motion program, use TA in the program and not rely on this parameter, unless keeping to a syntax standard that does not support this (e.g. RS-274 G-Codes). Specifying acceleration time in the program along with speed and move modes makes it much easier for later debugging.

If the specified S-curve time (see Ix88, below) is greater than half the specified acceleration time, the time used for commanded acceleration in blended moves will be twice the specified S-curve time. The acceleration time is also the minimum time for a blended move; if the distance on a feedrate- specified (F) move is so short that the calculated move time is less than the acceleration time, or the time of a time-specified (TM) move is less than the acceleration time, the move will be done in the acceleration time instead.

This will slow down the move The acceleration time will be extended automatically when any motor in the coordinate system is asked to exceed its maximum acceleration rate (Ix17) for a programmed LINEAR-mode move with I13=0 (no move segmentation). 122 I-Variables