omron — $$$ ***

PMAC Product Guide Note: Because this command immediately causes PMAC to enter its power-up/rest cycle, there is no acknowledging character ( or ) returned to the host. Examples: I130=60000 ; Change #1 proportional gain SAVE ; Save I-Variables to EAROM I130=80000 ; Change gain again $$$ ; Reset card I130 ; Request value of parameter 60000 ; PMAC reports current value, which is saved value (Put E51 on) $$$ ; Reset card I130 ; Request value of parameter 2000 ; PMAC reports current value, which is default $$$ *** Function : Global card reset and re-initialization Scope : Global Syntax : $$$*** This command performs a full reset of the card and reinitializes the memory.

All programs and other buffers are erased. All I-variables, encoder conversion table entries, and VME and DPRAM addressing parameters are returned to their factory defaults. (Previously saved values for these parameters are still held in EAROM and can be brought into active memory with a subsequent $$$ command). It will also recalculate the firmware checksum reference value and eliminate any PASSWORD that might have been entered. M-Variable definitions, P-Variable values, Q-Variable values, and axis definitions are not affected by this command. They can be cleared by separate commands (e.g. M0..1023->* , P0..1023=0 , Q0..1023=0 , UNDEFINE ALL ).

This command is useful particularly if the program buffers have become corrupted. It clears the buffers and buffer pointers so the files can be re-sent to PMAC. Regular backup of parameters and programs to the disk of a host computer is strongly encouraged so this type of recovery is possible. The PMAC Executive program has Save Full PMAC Configuration and Restore Full PMAC Configuration functions to make this process easy. With jumper E51 in non-default state (ON for PMAC-PC, -Lite, -VME, OFF for PMAC-STD), a PMAC with the Option CPU section (option 4A, 5A, or 5B) enters a special re-initialization mode called bootstrap mode when this command is given.

This mode permits the downloading of new firmware. In this mode, there are very few command options. To bypass the download operation in this mode, send a character to PMAC. This puts PMAC in the normal operational mode with the existing firmware. Factory default values for I-Variables, conversion table settings, and bus addresses for DPRAM and VME are copied from the firmware section of flash memory into active memory. The saved values of these values are not used, but they are kept in the user section of flash memory. Examples:

I130=60000 ; Set #1 proportional gain SAVE ; Save to non-volatile memory $$$*** ; Reset and re-initialize card I130 ; Request value of I130 2000 ; PMAC reports current value, which is default $$$ ; Normal reset of card 140 Online Commands