PMAC Product Guide Fourth Character Returned: Bit 11 Block Request: This bit is 1 when the motor has just entered a new move section, and is requesting that the upcoming section be calculated. It is 0 otherwise. It is primarily for internal use. Bit 10 Home Search in Progress: This bit is set to 1 when the motor is in a move searching for a trigger: a homing search move, a jog-until trigger, or a motion program move-until-trigger. It becomes 1 as soon as the calculations for the move have started, and becomes zero again as soon as the trigger has been found, or if the move is stopped by some other means.
This is not a good bit to observe to see if the full move is complete, because it will be 0 during the post-trigger portion of the move. Use the Home Complete and Desired Velocity Zero bits instead. Bits 8-9 These bits are used to store a pointer to the next data block for motor calculations. They are primarily for internal use. Fifth and Sixth Characters Returned: Bits 0-7 These bits are used to store a pointer to the next data block for motor calculations. They are primarily for internal use. Second Word Returned (Y:$0814, Y:$08D4, etc.) Seventh Character Returned: Bit 23 Assigned to Coordinate System:
This bit is 1 when the motor has been assigned to an axis in any coordinate system through an axis definition statement. It is 0 when the motor is not assigned to an axis in any coordinate system. Bits 20-22 (Coordinate System - 1) Number: These three bits together hold a value equal to the (Coordinate System number minus one) to which the motor is assigned. Bit 22 is the MSB, and bit 20 is the LSB. For instance, if the motor were assigned to an axis in Coordinate System 6, these bits would hold a value of 5: bit 22 =1, bit 21 = 0, and bit 20 = 1. Eighth Character Returned: Bits 16-19 (Reserved for future use) Ninth Character Returned:
Bit 15 (Reserved for future use) Bit 14 Amplifier Enabled: This bit is 1 when the outputs for this motor’s amplifier are enabled, either in open-loop or closed-loop mode (refer to Open-Loop Mode status bit to distinguish between the two cases). It is 0 when the outputs are disabled (killed). Bits 12-13 (Reserved for future use) Tenth Character Returned: Bit 11 Stopped on Position Limit: This bit is 1 if this motor has stopped because of either a software or a hardware position (overtravel) limit, even if the condition that caused the stop has gone away. It is 0 at all other times, even when into a limit but moving out of it. Bit 10 Home Complete:
This bit, set to 0 on power-up or reset, becomes 1 when the homing move successfully locates the home trigger. At this point in time, usually the motor is decelerating to a stop or moving to an offset from the trigger determined by Ix26. If a second homing move is done, this bit is set to 0 at the beginning of the move, and only becomes 1 again if that homing move successfully locates the home trigger. Use the Desired Velocity Zero bit and/or the In Position bit to monitor for the end of motor motion. Online Commands 145