PMAC Product Guide Bit 0 CIRCLE / SPLINE Move Mode: This bit is 1 if the coordinate system is in either CIRCLE or SPLINE move mode. (If bit 4 of this word is 0, this means CIRCLE mode; if bit 4 is 1, this means SPLINE mode.) This bit is 0 if the coordinate system is in a different move mode ( LINEAR , PVT , or RAPID .). See the table below. The states of bits 4, 1, and 0 in the different move modes are summarized in the following table: Examples: ?? ; Request coordinate system status words A8002A020010 ; PMAC responds; the following bits are true: ; Word 1 Bit 23: Z-axis used in feedrate calcs ; Bit 21: Y-axis used in feedrate calcs ; Bit 19: X-axis used in feedrate calcs ; Bit 5:
Radius vector incremental mode ; Bit 3: Move specified by time ; Bit 1: Single-step mode ; Word 2 Bit 17: In-position ; Bit 4: PVT/Spline mode ??? Function : Report global status words Scope : Global Syntax : ??? This command causes PMAC to return the global status bits in ASCII hexadecimal form. PMAC returns twelve characters, representing two status words. Each character represents four status bits. The first character represents Bits 20-23 of the first word, the second shows Bits 16-19; and so on, to the sixth character representing Bits 0-3. The seventh character represents Bits 20-23 of the second word; the twelfth character represents Bits 0-3 of the second word.
A bit has a value of 1 when the condition is true; 0 when false. The meaning of the individual status bits is: First Word Returned (X:$0003) First Character Returned: Bit 23 Real-Time Interrupt Active: This bit is 1 if PMAC is currently executing a real-time interrupt task (PLC 0 or motion program move planning). It is 0 if PMAC is executing some other task. Note: Communications can only happen outside of the real-time interrupt so polling this bit will always return a value of 0. This bit is for internal use. Bit 22 Real-Time Interrupt Re-entry:
This bit is 1 if a real-time interrupt task has taken long enough so that it was still executing when the next real-time interrupt came (I8+1 servo cycles later). It stays at 1 until the card is reset, or until this bit is changed manually to 0. If motion program calculations cause this, it is not a serious problem. If PLC 0 causes this (no motion programs running), it could be serious. 152 Online Commands Mode Bit 4 Bit 1 Bit 0 LINEAR 0 0 0 RAPID 0 1 0 SPLINE 1 0 1 CIRCLE1 0 0 1 CIRCLE2 0 1 1 PVT 1 1 0