PMAC Product Guide P1=0 ; Initialize part counter WHILE (P0 ; Loop once per part P1=P1+1 DATE Function : Report PROM firmware revision date. Scope : Global Syntax : DATE DAT This command causes PMAC to report the revision date of the PROM firmware revision it is using. The date is reported in the American style: mm/dd/yy (month/day/year). Example: DATE Ask PMAC for firmware revision date 07/22/92 PMAC responds with July 22, 1992 DEFINE TBUF Function : Create a buffer for axis transformation matrices. Scope : Global Syntax :

DEFINE TBUF {constant} DEF TBUF {constant} where {constant} is a positive integer representing the number of transformation matrices to create This command reserves space in PMAC’s memory for one or more axis transformation matrices. These matrices can be used for real-time translation, rotation, scaling, and mirroring of the X, Y, and Z axes of any coordinate system. A coordinate system selects which matrix to use with the TSELn command, where n is an integer from 1 to the number of matrices created here. Note: PMAC will reject this command, reporting an ERR003 if I6=1 or 3, if any ROTARYor GATHER buffer exists. Any of these buffers must be deleted first.

The number of long words of unused buffer memory can be found by issuing the SIZE command. Each defined matrix takes 21 words of memory. Example: DELETE GATHER DEF TBUF 1 DEFINE TBUF 8 DELETE GATHER Function : Erase the data gather buffer Scope : Global Syntax : DELETE GATHER DEL GAT This command causes the data-gathering buffer to be erased. The memory that was reserved is now de- allocated and is available for other buffers (motion programs, PLC programs, compensation tables, etc.). If Data Gathering is in progress (an ENDGATHER command has not been issued and the gather buffer has not been filled), PMAC will report an error on receipt of this command. Online Commands 159