PMAC Product Guide PMAC’s Executive Program inserts this command automatically at the top of a file when it uploads a buffer from PMAC into its editor, so the next download will not be hampered by an existing gather buffer. Use this command as well when creating a program file in the editor (see Examples, below). Note: When the executive program’s data gathering function operates, it reserves the entire open buffer space for gathered data automatically. When this has happened, no additional programs or program lines may be entered into PMAC’s buffer space until the DELETE GATHER command has freed this memory. Examples:
CLOSE ; Make sure no buffers are open DELETE GATHER ; Free memory OPEN PROG 50 ; Open new buffer for entry CLEAR ; Erase contents of buffer ... ; Enter new contents here DELETE TBUF Function : Delete buffer for axis transformation matrices. Scope : Global Syntax : DELETE TBUF DEL TBUF This command frees up the space in PMAC’s memory that was used for axis transformation matrices. These matrices can be used for real-time translation, rotation, scaling, and mirroring of the X, Y, and Z axes of any coordinate system. Note: PMAC will reject this command, reporting an ERR007 if I6=1 or 3, if any ROTARY or GATHER buffer exists. Any of these buffers must be deleted first. Examples:
DEL TBUF DELETE TBUF DISABLE PLC Function : Disable specified PLC programs Scope : Global Syntax : DISABLE PLC {constant}[,{constant}] DIS PLC {constant}[,{constant}] DISABLE PLC {constant}..{constant} DIS PLC {constant}..{constant} where {constant} is an integer from 0 to 31, representing the program number. This command causes PMAC to disable (stop executing) the specified PLC program or programs. PLC programs are specified by number and may be specified in a command singularly, in a list (separated by commas), or in a range of consecutively numbered programs. PLC programs can be re-enabled by using the ENABLE PLC command.
If a motion or PLC program buffer is open when this command is sent to PMAC, the command will be entered into that buffer for later execution. Examples: DISABLE PLC 1 DIS PLC 5 160 Online Commands