PMAC Product Guide B{data} Function : B-axis move Type : Motion program (PROG and ROT) Syntax : B{data} where {data} is a floating-point constant or expression representing the position or distance in user units for the U-axis. This command causes a move of the B-axis. (See {axis}{data} description in this section.) Program commands {axis}{data} , A , C , U , V , W , X , Y , Z , CALL , READ. BLOCKSTART Function : Mark start of stepping block Type : Motion program (PROG and ROT) Syntax : BLOCKSTART BSTART This statement allows for multiple moves to be done on a single STEP command.
Execution on a STEP command will proceed until the next BLOCKSTOP statement in the program (without BLOCKSTART , only a single servo command is executed on a STEP command). Also, if Ix92=1 (move blending disabled), all moves between BLOCKSTART and BLOCKSTOP will be blended together. This does not affect how a program is executed from a RUN command if Ix92=0. This structure is useful particularly for executing a single sequence of PVT mode moves because the individual segments do not end at zero velocity, making normal stepping very difficult. Examples: For the program segment:
BLOCKSTART INC X10:100 X20:100 X20:100 X10:0 BLOCKSTOP All four move segments will be executed on a single S command. BLOCKSTOP Function : Mark end of stepping block Type : Motion program (PROG and ROT) Syntax : BLOCKSTOP BSTOP This statement marks the end of the block of statements, begun with a BLOCKSTART , to be done on a single STEP command, or to be blended together even if Ix92=1 (move blending disabled). This does not affect how a program is executed from a RUN command if Ix92=1. Examples: See example under BLOCKSTART in this section. 204 Buffer Commands