PMAC Product Guide {message} is the ASCII text string to be displayed. This command causes PMAC to send the string contained in {message} to the display port (J1 connector) for the liquid crystal or vacuum-fluorescent display (Accessory 12 or equivalent). The optional constant value specifies the starting point for the string on the display; it has a range of 0 to 79, where 0 is upper left, 39 is upper right, 40 is lower left, and 79 is lower right. Examples: DISPLAY 10"Hello World" DISP "VALUE OF P1 IS" DISP 15, 8.3, P1 DISPLAY ... {variable} Function : Formatted display of variable value Type : Motion program (PROG and ROT), PLC program Syntax :
DISPLAY {constant}, {constant}.{constant}, {variable} DISP {constant}, {constant}.{constant}, {variable} where the first {constant} is an integer from 0 to 79 representing the starting location (character number) on the display. the second {constant} is an integer from 2 to 16 representing the total number of characters to be used to display the value (integer digits, decimal point, and fractional digits). the third {constant} is an integer from 0 to 9 (and at least two less than the second {constant} ) representing the number of fractional digits to be displayed. {variable} is the name of the variable to be displayed.
This command causes PMAC to send a formatted string containing the value of the specified variable to the display port. The value of any I, P, Q, or M-Variable may be displayed with this command. The first constant value specifies the starting point for the string on the display; it has a range of 0 to 79, where 0 is upper left, 39 is upper right, 40 is lower left, and 79 is lower right. The second constant specifies the number of characters to be used in displaying the value; it has a range of 2 to 16. The third constant specifies the number of places to the right of the decimal point; it has a range of 0 to 9, and must be at least two less than the number of characters.
The last thing specified in the statement is the name of the variable -- I, P, Q, or M. Examples: DISPLAY 0, 8.0, P50 DISPLAY 24, 2.0, M1 DISPLAY 40, 12.4, Q100 DWELL Function : Dwell for specified time Type : Motion program (PROG and ROT) Syntax : DWELL{data} DWE{data} where {data} is a non-negative floating point constant or expression representing the dwell time in milliseconds. This command causes the card to keep the commanded positions of all axes in the coordinate system constant for the time specified in {data} . There are three differences between DWELL and the similar DELAY command.
First, if the previous servo command was a blended move, there will be a TA time deceleration to a stop before the dwell time starts. Second, DWELL is not sensitive to a varying time base -- it always operates in 'real time' (as defined by Buffer Commands 211