omron — SPLINE2

PMAC Product Guide It is possible, particularly in PLC programs, to order the sending of messages faster than the port can handle them. This will almost always happen if the same SEND command is executed every scan through the PLC. For this reason, it is good practice to have at least one of the conditions that causes the SEND command to execute to be set false immediately to prevent execution of this SEND command on subsequent scans of the PLC. SPLINE1 Function : Put program in uniform cubic spline motion mode Type : Motion program (PROG and ROT) Syntax : SPLINE1 This modal command puts the program in cubic spline mode.

In SPLINE1 mode, each programmed move takes TA time (Ix87 is default) -- there is no feedrate specification allowed. Each move on each axis is computed as a cubic position trajectory in which the intermediate positions are relaxed somewhat so there are no velocity or acceleration discontinuities in blending the moves together. Before the first move in any series of consecutive moves, a starting move of TA time is added to blend smoothly from a stop. After the last move in any series of consecutive moves, an ending move of TA time is added to blend smoothly to a stop.

If the TA time is changed in the middle of a series of moves, there will be a stop generated, with an extra TA 1 move and an extra TA 2 move added. This command will take the program out of any of the other move modes ( LINEAR , CIRCLE , PVT , RAPID ). The program will stay in this mode until another move mode command is executed. Examples: RAPID X10 Y10 SPLINE1 TA100 X20 Y15 X32 Y21 X43 Y26 X50 Y30 DWELL100 RAPID X0 Y0 SPLINE2 Function : Put program in non-uniform cubic spline motion mode Type : Motion program (PROG and ROT) Syntax : SPLINE2 This modal command puts the program in non-uniform cubic spline mode.

This mode is virtually identical to the SPLINE1 uniform cubic spline mode described above, except that the TA segment time can vary in a continuous spline. This makes SPLINE2 mode more flexible than SPLINE1 mode, but it takes slightly more computation time. Examples: RAPID X10 Y10 SPLINE2 X20 Y15 TA100 X32 Y21 TA120 X43 Y26 TA87 X50 Y30 TA62 DWELL100 RAPID X0 Y0 236 Buffer Commands