omron — TA{data}

PMAC Product Guide STOP Function : Stop program execution Type : Motion program (PROG) Syntax : STOP This command suspends program execution, whether started by RUN or STEP , keeping the program counter pointing to the next line in the program, so that execution may be resumed with a RUN or STEP command. Examples: A10 B10 A20 B0 STOP A0 B0 TA{data} Function : Set acceleration time Type : Motion program (PROG and ROT) Syntax : TA{data} where {data} is a constant or expression representing the acceleration time in milliseconds This statement specifies the commanded acceleration time between blended moves ( LINEAR and CIRCLE mode), and from and to a stop for these moves.

In PVT and SPLINE1 mode moves, generally which are continually accelerating and decelerating, it specifies the actual move segment time. The units are milliseconds. PMAC will round the specified value to the nearest integer number of milliseconds when executing this command (no rounding is done in storing the value in the buffer). Note: Make sure the specified acceleration time (TA or 2*TS) is greater than zero, even if planning to rely on the maximum acceleration rate parameters (Ix17). A specified acceleration time of zero will cause a divide-by-zero error. The minimum specified time should be TA1 TS0 .

If the specified S-curve time (from TS , or Ix88) is greater than half the TA time, the time used for the acceleration for blended moves will be twice the specified S-curve time. The acceleration time is also the minimum time for a blended move; if the distance on a feedrate- specified ( F ) move is so short that the calculated move time is less than the acceleration time, or the time of a time-specified ( TM ) move is less than the acceleration time, the move will be done in the acceleration time instead. This will slow down the move. If TA controls the move time, it must be greater than the I13 time and the I8 period. Note:

The acceleration time will be extended automatically when any motor in the coordinate system is asked to exceed its maximum acceleration rate (Ix17) for a programmed LINEAR mode move with I13=0 (no move segmentation). A move executed in a program before any TA statement will use the default acceleration time specified by coordinate system I-Variable Ix87. In executing the TA command, PMAC rounds the specified value to the nearest integer number of milliseconds (there is no rounding done when storing the command in the buffer). Buffer Commands 237