sinee — 6.2Table of functional parameters

User Manual of EM730 Series Inverter 109 4: 1-8-E-2 (1 start bit + 8 data bits + 1 even parity check bit + 2 stop bits) 5: 1-8-O-2 (1 start bit + 8 data bits + 1 odd parity check bit + 2 stop bits) F10.03 485 communicatio n timeout 0.0s ~ 60.0s; 0.0: invalid (valid for the master-slave mode) s 0.0 ● 0x0A03 F10.04 Modbus response delay 1 ~ 20 ms 2 ● 0x0A04 F10.05 Options of master-slave communicatio n function 0: invalid 1: valid 0 〇 0x0A05 F10.06 Master-slave options 0: slave 1: host (Modbus protocol broadcast transmission) 0 〇 0x0A06 F10.07 Data sent by host 0: output frequency 1: set frequency 2: output torque 3: set torque 4: PID setting 5:

output current 1 〇 0x0A07 F10.08 Proportional factor of slave reception 0.00 ~ 10.00 (multiple) 1.00 ● 0x0A08 F10.09 Host sending interval 0.000 ~ 30.000 s 0.200 ● 0x0A09 F10.10 Communicatio n protocol option 0: Modbus-RTU protocol 0 × 0x0A0A F10.56 Options of 485 EEPROM writing 0-10: default operation (for commissioning) 11: writing not triggered (available after commissioning) 0 〇 0x0A38 F10.57 Enabling of SCI sending timeout resetting 0: invalid resetting 1: valid resetting 1 ● 0x0A39 F10.58 Delay time of SCI sending timeout resetting 110 ~10000 mS 150 ● 0x0A3A