sinee — 6.2Table of functional parameters

User Manual of EM730 Series Inverter 115 parameter 3 F12.41 Options of UP/DOWN zero crossing 0: invalid 1: valid 0 〇 0x0C29 F12.42 Frequency setting of digital potentiometer 0.00 to maximum frequency F00.16 Hz 0.00 × 0x0C2A F12.43 Digital potentiometer torque setting 0.00-|Digital torque setting F13.02| % 0.0 × 0x0C2B F12.45 UP/DOWN function options of keyboard Communicat ion High- speed pulse Analog quantity Digital frequen cy Mult i- segm ent spee d 00000 〇 0x0C2C 0 0 0 0 0 0: invalid 1: valid F12.48 Output frequency display 0:absolute value 1:positive/negative 1 ● 0x0C30 F13 Torque control parameter group F13.00 Speed/torque control options 0: speed control 1:

torque control 0 〇 0x0D00 F13.01 Options of torque setting source 0: digital torque setting F13.02 1: AI1 2: AI2 3: reserved 4: reserved 5: high frequency pulse input (X5) 6: communication setting 7: reserved 8: digital potentiometer setting (Full range of the items 1-6, corresponding to F13.02 digital torque setting) 0 〇 0x0D01 F13.02 Digital torque setting -200.0 ~ 200.0 % 100.0 ● 0x0D02