User Manual of EM730 Series Inverter The synthetic frequency is directly set to “AI (percentage) * synthetic frequency of main and auxiliary channels”. meaning. 100.00% is the percentage relative to the main and auxiliary synthetic frequency. For the details of AI1-AI2 and X5, refer to the F00.04 description. They have the same F00.13=5: High frequency pulse (PULSE) * synthetic frequency of main and auxiliary channels The synthetic frequency is directly set to “HDI (percentage) * synthetic frequency of main and auxiliary channels”. For the details of AI1-AI2 and X5, refer to the F00.04 description. They have the same meaning.
100.00% is the percentage relative to the main and auxiliary synthetic frequency. The acceleration time is the time for the output frequency to rise from 0.00Hz to the set value Fbase of F15.09 (reference frequency of the acceleration and deceleration time); and the deceleration time is the time for the output frequency to fall from Fbase to 0.00Hz, regardless of forward and reverse running. See Fig. 7-9. (a) Acceleration time 1 (b) Deceleration time 1 Fig.
7- 9 Acceleration and Deceleration Time 160 Function code Function code name Parameter description Unit Default setting Attribute mailing address F00.14 Acceleration time 1 0.00 ~ 650.00 (F15.13=0) 0.0 ~ 6500.0 (F15.13=1) 0 ~ 65000 (F15.13=2) s 15.00 ● 0x000E F00.15 Deceleration time 1 0.00 ~ 650.00 (F15.13=0) 0.0 ~ 6500.0 (F15.13=1) 0 ~ 65000 (F15.13=2) s 15.00 ● 0x000F