User Manual of EM730 Series Inverter 7.9 Multi-segment Speed and Simple PLC Parameter Group of F08 Group 227 F07.40 Steady-state undervoltage judgment delay time 5~6000 ms 20 〇 0x0728 F07.42 Short-circuit the ground to judge the setting value of the current 0.0~100.0 % 20 〇 0x072A Function code Function code name Parameter description Unit Default setting Attribute Mailing address F08.00 Multi-segment speed 1 0.00 to maximum frequency F00.16 Hz 0.00 ● 0x0800 F08.01 Multi-segment speed 2 0.00 to maximum frequency F00.16 Hz 5.00 ● 0x0801 F08.02 Multi-segment speed 3 0.00 to maximum frequency F00.16 Hz 10.00 ● 0x0802 F08.03 Multi-segment speed 4 0.00 to maximum frequency F00.16 Hz 15.00 ● 0x0803 F08.04 Multi-segment speed 5 0.00 to maximum frequency F00.16 Hz 20.00 ● 0x0804 F08.05 Multi-segment speed 6 0.00 to maximum frequency F00.16 Hz 25.00 ● 0x0805 F08.06 Multi-segment speed 7 0.00 to maximum frequency F00.16 Hz 30.00 ● 0x0806 F08.07 Multi-segment speed 8 0.00 to maximum frequency F00.16 Hz 35.00 ● 0x0807 F08.08 Multi-segment speed 9 0.00 to maximum frequency F00.16 Hz 40.00 ● 0x0808 F08.09 Multi- speed 10 0.00 to maximum frequency F00.16 Hz 45.00 ● 0x0809 F08.10 Multi-segment speed 11 0.00 to maximum frequency F00.16 Hz 50.00 ● 0x080A F08.11 Multi-segment speed 12 0.00 to maximum frequency F00.16 Hz 50.00 ● 0x080B F08.12 Multi-segment speed 13 0.00 to maximum frequency F00.16 Hz 50.00 ● 0x080C F08.13 Multi-segment speed 14 0.00 to maximum frequency F00.16 Hz 50.00 ● 0x080D