User Manual of EM730 Series Inverter The system has four groups (F00.14 and F00.15 in the first group) of acceleration and deceleration time options to meet different needs for normal operation. After completing the setting, the user can switch them via the combination of digital input functions “19: acceleration and deceleration time terminal 1” and “20: acceleration and deceleration time terminal 2”. For details, please see: Table 7-6 Function List of Multi-function Digital Input Terminals. As shown in Fig. 7- 33, the acceleration time is defined as the time of acceleration from Fig.
7-33 Schematic Diagram of Acceleration and Deceleration Time 0.00 Hz to the reference frequency of acceleration/deceleration time; and the deceleration time is defined as the time of deceleration from the reference frequency of acceleration/deceleration time to 0.00 Hz. The actual acceleration/deceleration time varies according to the ratio between the set frequency and reference frequency.
275 0.0 ~ 6500.0 (F15.13=1) 0 ~ 65000 (F15.13=2) F15.05 Acceleration time 3 0.00 ~ 650.00 (F15.13=0) 0.0 ~ 6500.0 (F15.13=1) 0 ~ 65000 (F15.13=2) s 15.00 ● 0x0F05 F15.06 Deceleration time 3 0.00 ~ 650.00 (F15.13=0) 0.0 ~ 6500.0 (F15.13=1) 0 ~ 65000 (F15.13=2) s 15.00 ● 0x0F06 F15.07 Acceleration time 4 0.00 ~ 650.00 (F15.13=0) 0.0 ~ 6500.0 (F15.13=1) 0 ~ 65000 (F15.13=2) s 15.00 ● 0x0F07 F15.08 Deceleration time 4 0.00 ~ 650.00 (F15.13=0) 0.0 ~ 6500.0 (F15.13=1) 0 ~ 65000 (F15.13=2) s 15.00 ● 0x0F08 F15.09 Fundamental frequency of acceleration and deceleration time 0: maximum frequency F00.16 1: 50.00Hz 2: set frequency 0 〇 0x0F09