sinee — 7.16Auxiliary Function Parameter Group of F15 Group

User Manual of EM730 Series Inverter The reference frequency of acceleration/deceleration time is set by function code F15.09 that represents the reference frequency of acceleration/deceleration time. If F15.09=0, the reference frequency depends on the function code F00.16 (maximum frequency). Assuming F00.16=100.00Hz, the acceleration (deceleration) time is expressed as the time for the output frequency to increase (decrease) from 0.00Hz (100.00Hz) to 100.00Hz (0.00Hz). If F15.09=2, the reference frequency depends on the function code F18.01 (set frequency).

Assuming F18.01=100.00Hz, the acceleration (deceleration) time is expressed as the time for the output frequency to increase (decrease) from 0.00Hz (100.00Hz) to 100.00Hz (0.00Hz). acceleration/deceleration time terminals (19: acceleration and deceleration time terminal 1; 20: If the motor 1 is running at the normal (e.g. non-PLC/PID) speed (e.g. non-torque) and the acceleration and deceleration time terminal 2) are invalid, the acceleration/deceleration time 1 and acceleration/deceleration time 2 can be switched by setting F15.10 to 1, as detailed in Fig. 7- 34. Fig.

7-34 Schematic Diagram of Automatic Switching of Acceleration and Deceleration Time During acceleration, if the output frequency is less than the switching frequency of the acceleration time 1 and 2 (F15.11), the acceleration time 1 will be the current valid acceleration 276 Function code Function code name Parameter description Unit Default setting Attribute Mailing address F15.10 Automatic switching of acceleration and deceleration time 0: invalid 1: valid 0 〇 0x0F0A F15.11 Switching frequency of acceleration time 1 and 2 0.00 to maximum frequency F00.16 Hz 0.00 ● 0x0F0B F15.12 Switching frequency of deceleration time 1 and 2 0.00 to maximum frequency F00.16 Hz 0.00 ● 0x0F0C