User Manual of EM730 Series Inverter 298 2: AI2 5: High frequency pulse input (X5) 6: Main frequency communication given (percentage) 7: Main frequency communication given (direct frequency setting) 8: Digital potentiometer given F00.14 Acceleration time 1 0.00~650.00 (F15.13=0) 0.0~6500.0(F15.13=1) 0~65000(F15.13=2) s 2.00 ● 0x000E F00.15 Deceleration time 1 0.00~650.00 (F15.13=0) 0.0~6500.0(F15.13=1) 0~65000(F15.13=2) s 2.00 ● 0x000F F02.02 X3 Digital input function selection See the input terminal function table for details. 23 〇 0x0202 F05.00 V/F curve setting 0: Straight line V/F 1: Multi-point broken line V/F 2: 1.3 power V/F 3: 1.7 power V/F 4: Square V/F 5:
VF complete separation mode (Ud=0, Uq=K*t=separation voltage source voltage) 6: VF semi-separation mode (Ud=0, Uq=K*t=F/Fe*2*separa tion voltage source 1 〇 0x0500