sinee — 6.2Table of functional parameters

User Manual of EM730 Series Inverter 73 auxiliary frequency source B in main and auxiliary operation F00.10 Gain of main frequency source 0.0~300.0 % 100.0 ● 0x000A F00.11 Gain of auxiliary frequency source 0.0~300.0 % 100.0 ● 0x000B F00.12 Synthetic gain of main and auxiliary frequency sources 0.0~300.0 % 100.0 ● 0x000C F00.13 Analog adjustment of synthetic frequency 0: synthetic frequency of main and auxiliary channels 1: AI1 * synthetic frequency of main and auxiliary channels 2: AI2 * synthetic frequency of main and auxiliary channels 3: reserved 4: reserved 5:

high frequency pulse (PULSE) * synthetic frequency of main and auxiliary channels 0 〇 0x000D F00.14 Acceleration time 1 0.00 ~ 650.00 (F15.13=0) 0.0 ~ 6500.0 (F15.13=1) 0 ~ 65000 (F15.13=2) s 15.00 ● 0x000E F00.15 Deceleration time 1 0.00 ~ 650.00 (F15.13=0) 0.0 ~ 6500.0 (F15.13=1) 0 ~ 65000 (F15.13=2) s 15.00 ● 0x000F F00.16 Maximum frequency 1.00~600.00/1.0~3000.0 Hz 50.00 〇 0x0010 F00.17 Options of upper frequency limit control 0: set by F00.18 1:AI1 2:AI2 3: reserved 4: reserved 5: high frequency pulse input (X5) 6: communication setting (percentage) 0 〇 0x0011