sinee — 6.2Table of functional parameters

User Manual of EM730 Series Inverter 74 7: communication setting (direct frequency) F00.18 Upper frequency limit lower frequency limit F00.19 to maximum frequency F00.16 Hz 50.00 ● 0x0012 F00.19 Lower frequency limit 0.00 to upper frequency limit F00.18 Hz 0.00 ● 0x0013 F00.20 Running direction 0: consistent direction 1: opposite direction 0 ● 0x0014 F00.21 Reverse control 0: allow forward/reverse running 1: prohibit reversing 0 〇 0x0015 F00.22 Duration of forward and reverse dead zone 0.00~650.00 s 0.00 ● 0x0016 F00.23 Carrier frequency 1.0 ~ 16.0 (rated power of the inverter: 0.75-4.00kW) 1.0 ~ 10.0 (rated power of the inverter:

5.50~7.50kW) 1.0 ~ 8.0 (rated power of inverter 11.00 - 45.00kW) 1.0 ~ 4.0 (rated power of inverter 55.00 - 90.00kW) 1.0 ~ 3.0 (rated power of inverter: 110.00 and above) kHz 4.0 (0.75 and below ) /2.0 ● 0x0017 F00.24 Automatic adjustment of carrier frequency 0: invalid 1: valid 1 2: valid 2 1 〇 0x0018 F00.25 Noise suppression of carrier frequency 0: invalid 1: noise suppression of carrier frequency mode 1 2: noise suppression of carrier frequency mode 2 0 〇 0x0019 F00.26 Noise suppression width 1~20 Hz 1 ● 0x001A F00.27 Noise suppression intensity 0: invalid 0~10: noise suppression of carrier frequency mode 1 0~ 4:

noise suppression of carrier frequency mode 2 % 2 ● 0x001B F00.28 Options of 0: parameter group of motor 1 0 〇 0x001C