User Manual of EM730 Series Inverter 79 27: clearing of regular running time 28: speed control/torque control switching 29: torque control prohibition 30: motor 1/motor 2 switching 31: resetting of simple PLC status (running from the first segment, with the running time cleared) 32: simple PLC time pause (keep running at current segment) 33: reserved 34: counter input (≤250Hz) 35: high-speed count input (≤100kHz, only valid for X5) 36: count clearing 37: length counter input (≤250Hz) 38: High-speed length counting input (≤100kHz, only valid for X5) 39: reset length (clear by meter) 40: pulse input (≤100kHz, only valid for X5) 41: process PID pause 42: process PID integral pause 43:
PID parameter switching 44: PID positive/negative switching 45: stop and DC braking 46: DC braking at stop 47: immediate DC braking 48: fastest deceleration to stop 49: reserved 50: external stop 51: switching of main frequency source to digital frequency setting 52: switching of main frequency source to AI1 53: switching of main frequency source to AI2 54: reserved 55: switching of main frequency source to high-frequency pulse input 56: switching of main frequency source to communication setting 57: inverter enabling 58: prohibit reversing and prohibit enabling 68: disable reversal 69: prohibit reversing 70: input terminal expansion 121: external material cutoff signal