sinee — 6.2Table of functional parameters

User Manual of EM730 Series Inverter 97 F07.10 Check time for instantaneous stop/no-stop recovery voltage 0.00 ~ 100.00 s 0.50 ● 0x070A F07.11 Current limit control 0: invalid 1: limit mode 1 2: limit mode 2 2 〇 0x070B F07.12 Current limit level 20.0-180.0(100.0 = the rated current of inverter) % 150.0 ● 0x070C F07.13 Quick current limit options 0: invalid 1: valid 0 〇 0x070D F07.14 Protection retries 0-20; 0: Disable protection retry 0 〇 0x070E F07.15 Options of digital output action in protection retries 0: no action 1:

action 0 〇 0x070F F07.16 Interval of protection retries 0.01 ~ 30.00 s 0.50 ● 0x0710 F07.17 Restoration time of protection retries 0.01 ~ 30.00 s 10.00 ● 0x0711 F07.18 Action option of protection E08 * E07 * E02 E06 E05 E 0 4 0 *0 *0000 〇 0x0712 0: allow protection retry 1: disable protection retry F07.19 Action option 1 of protection E21 E16 E15 E14 E13 * E08 E 0 7 000 00*00 〇 0x0713 0: free stop 1: stop according to stop mode F07.20 Action option 2 of protection E28 E27 * E23 00*0 〇 0x0714 0: free stop 1: stop according to stop mode