User Manual of EM760 High-Performance Inverter 303 F06.77 Low speed correction factor of rotor resistor of asynchronous motor 10.0~500.0 % 100.0 ● 0x064D F06.78 Slip gain switching frequency of asynchronous motor 0.10~Fmax Hz 5.00 O 0x064E F06.79 Speed ring differential time constant ASR Td1 _ 0.000~10.000 S 0 ● 0x064F F06.80 Speed ring differential time constant ASR Td _ 0.000~10.000 S 0 ● 0x0650 F06.81 Speed ring differential limit 0.0~150.0 % 0 ● 0x0651 F06.82 Filtering time constant of bus voltage 0.0~1500.0 ms 8.0 ● 0x0652 F07 Protection function setting group F07.00 Protection shield E20 E 22 E1 3 E0 6 E05 E04 E07 E08 00000000 O 0x0700 0: valid protection 1:
shielded protection F07.01 Motor overload protection gain 0.20~10.00 1.00 ● 0x0701 F07.02 Motor overload pre- alarm coefficient 50~100 % 80 ● 0x0702 F07.03 Motor temperature sensor type 0: No temperature sensor 1: PT100 2: PT1000 3: KTY84-130/150 4: PTC-130/150 0 ● 0x0703 F07.04 Motor overheat protectionthreshold 0~200 ℃ 110 ● 0x0704 F07.05 Motor overheat pre- alarm threshold 0~200 ℃ 90 ● 0x0705