User Manual of EM760 High-Performance Inverter 307 F08.03 Multi-segment speed 4 0.00 to maximum frequency F00.16 Hz 15.00 ● 0x0803 F08.04 Multi-segment speed 5 0.00 to maximum frequency F00.16 Hz 20.00 ● 0x0804 F08.05 Multi-segment speed 6 0.00 to maximum frequency F00.16 Hz 25.00 ● 0x0805 F08.06 Multi-segment speed 7 0.00 to maximum frequency F00.16 Hz 30.00 ● 0x0806 F08.07 Multi-segment speed 8 0.00 to maximum frequency F00.16 Hz 35.00 ● 0x0807 F08.08 Multi-segment speed 9 0.00 to maximum frequency F00.16 Hz 40.00 ● 0x0808 F08.09 Multi- speed 10 0.00 to maximum frequency F00.16 Hz 45.00 ● 0x0809 F08.10 Multi-segment speed 11 0.00 to maximum frequency F00.16 Hz 50.00 ● 0x080A F08.11 Multi-segment speed 12 0.00 to maximum frequency F00.16 Hz 50.00 ● 0x080B F08.12 Multi-segment speed 13 0.00 to maximum frequency F00.16 Hz 50.00 ● 0x080C F08.13 Multi-segment speed 14 0.00 to maximum frequency F00.16 Hz 50.00 ● 0x080D F08.14 Multi-segment speed 15 0.00 to maximum frequency F00.16 Hz 50.00 ● 0x080E F08.15 Simple PLC running mode 0:
stop after a single run 1: stop after a limited number of cycles 2: run at the last segment after a limited number of cycles 3: continuous cycles 0 ● 0x080F F08.16 Limited number of cycles 1~10000 1 ● 0x0810 F08.17 Simple PLC memory options Ones place: Stop memory options 0: no memory (from the first segment) 1: memory (from the moment of stop) Tens place: Power-down memory options 0: no memory (from the first segment) 1: Memory (from the power-down moment) 0 ● 0x0811 F08.18 Simple PLC time unit 0: s (second) 1: min (minute) 0 ● 0x0812 F08.19 Setting of the first segment Ones place: Running direction options 0 ● 0x0813