4-2 Function Mode 4 Functions *1. The Inverter's rated current is "1000". *2. The second decimal place is ignored when the value is over 10000 (100.0 seconds). 4-86 Register No. Function name Parameter No. R/W function Data Resolution 00B7h AM selection C028 R/W 0: F (Output frequency) 1: A (Output current) 00B8h Multi-function output terminal P1 contact selection C031 R/W 0: NO 1: NC 00B9h Multi-function output terminal P2 contact selection C032 R/W 0: NO 1: NC 00BAh Relay output (MA, MB) contact selection C036 R/W 0: NO 1:
NC 00BBh Overload warning level C041 R/W 0 to 20000 *1 0.01 [%] 00BCh Arrival frequency during acceleration C042 R/W 0 to 4000 0.1 [Hz] 00BDh Arrival frequency during deceleration C043 R/W 0 to 4000 0.1 [Hz] 00BEh PID deviation excessive level C044 R/W 0 to 1000 0.1 [%] 00C0h Not used 00C1h Not used 00C2h Not used 00C3h Not used 00C4h Not used 00C5h Not used 00C6h Not used 00C7h FV adjustment C081 R/W 0 to 2000 0.1 [%] 00C8h FI adjustment C082 R/W 0 to 2000 0.1 [%] 00C9h AM offset adjustment C086 R/W 0 to 100 0.1 [V] 00CAh Not used 00CBh Not used 00CCh Not used 00CDh Not used 00CEh Not used 00CFh UP/DWN selection C101 R/W 0:
Does not store the frequency data 1: Stores the frequency data 000Dh Reset selection C102 R/W 0: Trip reset at power-on 1: Trip reset at power-off 2: Enabled only during trip (Reset at power-on) 00D1h Not used 00D2h Not used