omron — Communication Function

4-2 Function Mode 4 Functions *1. The Inverter's rated current is "1000". *2. The second decimal place is ignored when the value is over 10000 (100.0 seconds). * Stores the value changed by the communication. For details, refer to "To Save the Change to the Holding Register (Enter Command)" (page 4-75). 4-87 Register No. Function name Parameter No. R/W function Data Resolution 00D3h Not used    00D4h Not used    00D5h Not used    00D6h Not used    00D7h Not used    00D8h Not used    00D9h Motor capacity selection H003 R/W 00: 0.2/02: 0.4/04: 0.75/06: 1.5/07: 2.2/ 09: 3.7/11: 5.5/12:

7.5  00DAh 2nd motor capacity selection H203 R/W  00DBh Motor pole number selection H004 R/W 2/4/6/8  00DCh 2nd motor pole number selection H204 R/W  00DDh Stabilization parameter H006 R/W 0 to 255 1. 00DEh 2nd stabilization parameter H206 R/W 0 to 255 1. Register No. Function name Parameter No. R/W Data Data resolution 0100h Fault monitor 1 d081 R Trip monitor 1: Factor code  0101h R Trip monitor 1: Frequency 0.1 [Hz] 0102h R Trip monitor 1: Current 0.1 [%] 0103h R Trip monitor 1: Voltage 0.1 [V] 0104h R Trip monitor 1: Run time (H) 1. [h] 0105h R Trip monitor 1: Run time (L) 0106h R Trip monitor 1: ON time (H) 1. [h] 0107h R Trip monitor 1:

ON time (L) 0108h Fault monitor 2 d082 R Trip monitor 2: Factor code  0109h R Trip monitor 2: Frequency 0.1 [Hz] 010Ah R Trip monitor 2: Current 0.1 [%] 010Bh R Trip monitor 2: Voltage 0.1 [V] 010Ch R Trip monitor 2: Run time (H) 1. [h] 010Dh R Trip monitor 2: Run time (L) 010Eh R Trip monitor 2: ON time (H) 1. [h] 010Fh R Trip monitor 2: ON time (L)