omron — 7-1 Standard Specification List

7-1 Standard Specification List 7 Specifications *1. The applicable motor is a 3-phase standard motor. For using any other type, be sure that the rated current does not exceed that of the Inverter. *2. Output voltage decreases according to the level of the power supply voltage. *3. The braking torque at the time of capacitor feedback is an average deceleration torque at the shortest deceleration (when it stops from 50 Hz), not a continuous regeneration torque. Also, the average deceleration torque varies depending on the motor loss. The value is reduced in operation at over 50 Hz. Note that no braking resistor is built into the Inverter.

If you need a larger regenerative torque, use an optionally available braking resistor. *4. Protection method complies with JEM 1030. 7-3 Item Specifications Input signal Digital Operator signal Frequency settings Setting with the FREQ adjuster and the Increment/Decrement keys on the Digital Operator, variable resistance from 1 to 2 kΩ (2 W), 0 to 10 V DC (input impedance 10 kΩ), 4 to 20 mA (input impedance 250 Ω), communication through an RS-485 port (Modbus communication).

Forward/ Reverse Run/Stop Forward/Stop via the RUN/STOP keys (command selection for Forward or Reverse), Reverse/Stop available at the time of terminal allocation (selectable from 1NO or 1NC), Run/Stop through external communication.

Multi-function input FW (forward), RV (reverse), CF1 to CF4 (multi-step speed), RS (reset input), AT (current input selection), USP (USP function), EXT (external trip), OPE (forced OPE mode), STA (3-wire startup), STP (3-wire stop), F/R (3-wire forward/reverse), FRS (free run stop), JG (jogging), 2CH (2-step acceleration/deceleration), DB (external DC injection braking), SET (2nd control function), UP (UP/DWN function accelerated), DWN (UP/DWN function decelerated), PID (PID enabled/disabled), PIDC (PID deviation clear), PTC (thermistor input), UDC (UP/DWN function data clear), SFT (soft lock), ADD (frequency addition), F-TM (forced terminal block), RDY (operation ready), SP-SET (special setting) Output signal Multi-function output RUN (signal during operation), FA1 (frequency arrival signal), FA2 (over set frequency arrival signal), OL (overload warning signal), OD (PID excess deviation signal), AL (alarm output), ODC (communication option disconnected), FBV (PID FB status output), NDc (Network error), LOG (Logic operation output) Frequency monitor Analog meter (0 to 10 V DC, 1 mA max.), Frequency/Current signals are selectable via the analog output terminal.

Relay output The relay (SPDT contact) outputs signals corresponding to the multi-function output. Other functions AVR function, V/f characteristic selection, line acceleration/deceleration, upper/lower limit, 16-step speeds, starting frequency adjustment, jogging operation, carrier frequency adjustment, PID control, frequency jump, analog gain/bias adjustment, S-shape acceleration/deceleration, electronic thermal level adjustment, retry function, automatic torque boost, trip monitor, soft lock function, frequency conversion display, USP function, 2nd control function, motor rotation speed UP/DWN, fan ON/OFF function General specifications Ambient temperature -10°C to 40°C (Carrier frequency:

5 kHz max.) -10°C to 50°C (Both the carrier frequency and output current need to be reduced) *7 Ambient storage temperature -20°C to 65°C (short-time temperature during transport) Humidity 20% to 90% RH Vibration 5.9 m/s2 (0.6G), 10 to 55 Hz (Complies with the test method specified in JIS C0040 (1999).) Location At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust) Applicable standard Complies with UL, cUL, CE standards. (Insulation distance) Options Noise filter, AC/DC reactors, regenerative braking unit and resistor, etc.