4-1 Monitor Mode Multi-function Input Monitor [d005] Displays the input status of the multi-function input terminals. C011 to C016 (contact selection) are excluded. (Example) Multi-function input terminal S2,S1:ON Multi-function input terminal S6,S5,S4,S3:OFF ON Display : OFF OFF : ON S6 S1 S2 S3 S4 S5 (OFF) (OFF)(OFF)(OFF)(ON) (ON) 4 Multi-function input monitor Multi-function Output Monitor [d006] Functions Displays the output status of the multi-function output terminals and relay output terminals. C031, C032, and C036 (contact selection) are excluded. This monitor indicates the signal status of the functions (C021 and C022) allocated to each multi- function output terminal.
(Example) Multi-function output terminal P2,P1 : ON Relay output terminal MA : OFF Display ON OFF :ON :OFF (OFF) (ON) P1 MA (ON) P2 Multi-function output monitor Output Frequency Monitor (After Conversion) [d007] Displays a conversion value obtained by multiplying the Inverter output frequency by the coefficient set in [b086]. Displayed value = "Output frequency [d001]" Ч "Frequency conversion coefficient [b086]" (Display) [d007] 0.00 to 99.99 : Displays in increments of 0.01. 100.0 to 999.9 : Displays in increments of 0.1. 1000. to 9999. : Displays in increments of 1. 1000 to 3996 : Displays in increments of 10. (Setting range) [b086] 0.1 to 99.9: Can be set in increments of 0.1.
(Example) When the output frequency [d001] = 50.0 Hz, and the frequency conversion coefficient [b086] = 1.1, the monitor [d007] displays "55.0" through 50.0 Ч 1.1 = 55.0. 4-2