Chapter 5: Advanced Serverboard Setup Power Supply Fail Detect Enable/Disable The system can notify you in the event of a power supply failure. This feature assumes that three redundant power supply units are installed in the chas- sis. If you only have one or two power supplies installed, you should disable the function with the J3P header to pre- vent false alarms. See the table on the right for jumper settings. I 2 C to PCI Enable/Disable The JI 2 C1/2 pair of jumpers allows you to connect the System Manage- ment Bus to the PCI expansion slots. The default setting is closed (on) for both jumpers to enable the connec- tion.

Both connectors must be set the same (JI 2 C1 is for data and JI 2 C2 is for the clock). See the table on right for jumper settings. Watch Dog JWD controls Watch Dog, a system monitor that takes action when a soft- ware application freezes the system. Jumping pins 1-2 will cause WD to reset the system if an application is hung up. Jumping pins 2-3 will gen- erate a non-maskable interrupt signal for the application that is hung up. Note: When enabled, the user needs to write their own application software in or- der to disable the Watch Dog timer. See the table on the right for jumper settings. Watch Dog can also be enabled via BIOS.

5-21 Power Supply Fail Detect Jumper Settings (J3P) Jumper Setting Defi nition Open Disabled Closed Enabled I2C to PCI Enable/Disable Jumper Settings (JI2C1/2) Jumper Setting Defi nition Closed Enabled Open Disabled Watch Dog Jumper Settings (JWD) Jumper Setting Defi nition Pins 1-2 Reset Pins 2-3 NMI Open Disabled