— Supermicro SuperWorkstation 5046A-X User's Manual (1.0a)

S uper W orkstation 5046A-X User's Manual Overheat/Fan Fail LED (OH) Connect an LED to pins 7 and 8 of JF1 to provide advanced warning of chassis overheating or fan failure. Refer to the table on the right for pin defi nitions. NIC1 (GLAN) LED The LED connections for the GB LAN port are on pins 11 and 12 of JF1. At- tach an LED cable to display network activity. See the table on the right for pin defi nitions. HDD LED The HDD LED connection is located on pins 13 and 14 of JF1. This LED is used to display all IDE and SATA activity. See the table on the right for pin defi nitions. Power On LED The Power On LED connector is lo- cated on pins 15 and 16 of JF1 (use JLED for a 3-pin connector).

This connection is used to provide LED indication of power being supplied to the system. See the table on the right for pin defi nitions. Chassis Intrusion The Chassis Intrusion header is des- ignated JL1.

Attach an appropriate cable from the chassis to inform you of a chassis intrusion when the chas- sis is opened 5-14 OH/Fan Fail LED Pin Defi nitions (JF1) Pin# Defi nition 7 Vcc 8 Ground OH/Fan Fail Indicator Status State Defi nition Off Normal On Overheat Flash- ing Fan Fail NIC1 LED Pin Defi nitions (JF1) Pin# Defi nition 11 Vcc 12 Ground HDD LED Pin Defi nitions (JF1) Pin# Defi nition 13 Vcc 14 HD Active Power LED Pin Defi nitions (JF1) Pin# Defi nition 15 5V Stby 16 Control Chassis Intrusion Pin Defi nitions (JL1) Pin# Defi nition 1 Intrusion Input 2 Ground