— Supermicro SuperWorkstation 5046A-X User's Manual (1.0a)

Chapter 7: BIOS devices. ASK IR (Amplitude Shifted Keying Infra-Red) is a protocol compatible with Sharp® branded PDAs and other infra-red devices. Floppy Controller Select Enabled to enable the onboard Floppy Controller. The options are Enabled and Disabled. X Remote Access Confi guration Remote Access This feature allows the user to enable the function of Remote Access. The op- tions are Disabled and Enabled. If the item Remote Access is set to Enabled, the following items will display: Serial Port Number This feature allows the user decide which serial port to be used for Console Redirection. The options are COM 1 , and COM 2.

Serial Port Mode This feature allows the user to set the serial port mode for Console Redirection. The options are 115200 8, n 1 ; 57600 8, n, 1; 38400 8, n, 1; 19200 8, n, 1; and 9600 8, n, 1. Flow Control options are None , Hardware, and Software. This feature allows the user to set the fl ow control for Console Redirection. The Redirection After BIOS POST Select Disabled to turn off Console Redirection after Power_On_Self_Test (POST). Select Always to keep Console Redirection active all the time after POST. (Note: This setting may not be supported by some operating systems.) Select Boot Loader to keep Console Redirection active during POST and Boot Loader.

The options are Disabled, Boot Loader, and Always . Terminal Type This feature allows the user to select the target terminal type for Console Redi- rection. The options are ANSI, VT100 , and VT-UTF8. VT-UTF8 Combo Key Support A terminal keyboard defi nition that provides a way to send commands from a remote console. Available options are Enabled and Disabled. 7-17