H8QG6/i+-F Serverboard User's Manual Reset Connector The reset connector is located on pins 3 and 4 of JF1 and attaches to the reset switch on the computer chassis. See the table on the right for pin defi nitions. Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin defi nitions. Overheat (OH)/Fan Fail/PWR Fail/ UID LED Connect an LED cable to pins 7 and 8 of JF1 to use the Overheat/Fan Fail/ Power Fail and UID LED connections. The Red LED on pin 8 provides warnings of an overheat, fan failure or power failure. The Blue LED on pin 8 works as the UID LED indicator for the front panel UID switch.
Refer to the table on the right for pin defi nitions. NIC2 (Link/Activity) LED The LED connections for LAN2 link/ activity are on pins 9 and 10 of JF1. Attach LAN LED cables to display network activity. See the table on the right for pin defi nitions. NIC1 (Link/Activity) LED The LED connections for LAN1 link/ activity are on pins 11 and 12 of JF1. Attach LAN LED cables to display network activity. See the table on the right for pin defi nitions.
2-14 Reset Button Pin Defi nitions (JF1) Pin# Defi nition 3 Reset 4 Ground PWR Fail LED Pin Defi nitions (JF1) Pin# Defi nition 5 3.3V 6 Power Fail LED OH/Fan Fail/ PWR Fail (Red) LED and UID (Blue) LED Pin Defi nitions (JF1) Pin# Defi nition 7 Vcc 8 OH/Fan Fail/PWS Fail (Red) LED and UID (Blue) LED OH/Fan Fail/PWR Fail LED Status (Red LED) State Indication Off Normal On Overheat Flashing Fan Fail NIC2 LED Pin Defi nitions (JF1) Pin# Defi nition 9 Activity 10 Link NIC1 LED Pin Defi nitions (JF1) Pin# Defi nition 11 Activity 12 Link