3-7 Parameter List 3 Operation 3-20 Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Page d015 Integrated power monitor 0.0 to 999.9 1000. to 9999. 1000 to 9999 (10000 to 99990) 100 to 999 (100000 to 999000) 4-4 d016 Total RUN time 0. to 9999. 1000 to 9999 (10000 to 99990) 100 to 999 (100000 to 999000) h 4-4 d017 Power ON time monitor 0. to 9999. 1000 to 9999 (10000 to 99990) 100 to 999 (100000 to 999000) h 4-5 d018 Fin temperature monitor -020. to 200.0 °C 4-5 d019 Motor temperature monitor -020. to 200.0 °C 4-5 d022 Life assessment monitor ON 1: Capacitor on the main circuit board OFF2:
Cooling fan rotation speed reduced 2 1 4-5 d023 Not used d024 Not used d025 Not used d026 Not used d027 Not used d028 Pulse counter monitor 0 to 2147483647 (Displays MSB 4 digits) 4-5 d029 Position command monitor -1073741823 to 1073741823 (Displays MSB 4 digits including "-") 4-6 d030 Current position monitor -1073741823 to 1073741823 (Displays MSB 4 digits including "-") 4-6 4-128 d080 Fault frequency monitor 0. to 9999.
1000 to 6553 (10000 to 65530) Time 4-6 d081 Fault monitor 1 (Latest) Error code (condition of occurrence) →Output frequency [Hz] → Output current [A] →Internal DC voltage [V] →RUN time [h] →ON time [h] 4-6 d082 Fault monitor 2 4-6 d083 Fault monitor 3 4-6 d084 Fault monitor 4 4-6 d085 Fault monitor 5 4-6 d086 Fault monitor 6 4-6 d090 Warning monitor Warning code 4-7 d102 DC voltage monitor 0.0 to 999.9 V 4-7 d103 Regenerative braking load rate monitor 0.0 to 100.0 % 4-7