3-7 Parameter List 3 Operation * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-29 Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Page External frequency adjustment A101 FI start frequency 0.00 to 99.99 100.0 to 400.0 0.00 No Hz 4-14 A102 FI end frequency 0.00 No Hz A103 FI start ratio 0. to FI end ratio 20. No % A104 FI end ratio FI start ratio to 100. 100. No % A105 FI start selection 00: Use FI start frequency [A101] 01: 0 Hz 00 No A111 FE start frequency -400. to -100.
-99.9 to 0.00 to 99.99 100.0 to 400.0 0.00 No Hz 4-15 A112 FE end frequency 0.00 No Hz External frequency adjustment A113 FE start ratio -100. to FE end ratio -100. No % A114 FE end ratio FE start ratio to 100. 100. No % Acceleration/Deceleration A131 Acceleration curve parameter 01 (small curve) to 10 (large curve) 02 No 4-39 A132 Deceleration curve parameter 02 No Operation frequency A141 Operation frequency input A setting 00: Digital Operator (F001) 01: Digital Operator (FREQ adjuster) (Enabled when 3G3AX-OP01 is used.) 02: Input FV 03: Input FI 04: RS485 communication 05: Option 1 06: Option 2 07:
Pulse train frequency 02 No 4-41 A142 Operation frequency input B setting 03 No A143 Operator selection 00: Addition (A + B) 01: Subtraction (A - B) 02: Multiplication (A × B) 00 No A145 Frequency addition amount 0.00 to 99.99 100.0 to 400.0 0.00 No Hz 4-41 A146 Frequency addition direction 00: Add A145 value to output frequency 01: Subtract A145 value from output frequency 00 No