omron — Extended Function Mode

3-7 Parameter List 3 Operation * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-33 Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Page Others b034 RUN time/Power ON time setting 0. to 9999. (0 to 99990) 1000 to 6553 (10000 to 655300) 0. No h 4-51 b035 Rotation direction limit selection 00: Forward and Reverse are enabled 01: Only Forward is enabled. 02: Only Reverse is enabled. 00 No  4-52 b036 Reduced voltage startup selection 0 (Reduced voltage startup time: small) to 255 (Reduced voltage startup time: large) 6 No  4-52 Others b037 Display selection 00:

Complete display 01: Individual display of functions 02: User setting 03: Data comparison display 04: Basic display 04 No  4-53 b038 Initial screen selection 00: Screen when the Enter key was pressed last 01: d001 02: d002 03: d003 04: d007 05: F001 01 No  4-56 b039 User parameter automatic setting function selection 00: Disabled 01: Enabled 00 No  4-56 Torque limit b040 Torque limit selection 00: Four-quadrant separate setting 01: Terminal switch 02: Analog input 03: Option 1 04: Option 2 00 No - 4-56 4-58 b041 Torque limit 1 (Four-quadrant mode forward power running) 0. to 200. no (Torque limit disabled) 150.

No % 4-56 4-59 b042 Torque limit 2 (Four-quadrant mode reverse regeneration) 0. to 200. no (Torque limit disabled) 150. No % 4-57 4-59 b043 Torque limit 3 (Four-quadrant mode reverse power running) 0. to 200. no (Torque limit disabled) 150. No % b044 Torque limit 4 (Four-quadrant mode forward regeneration) 0. to 200. no (Torque limit disabled) 150. No % b045 Torque LADSTOP selection 00: Disabled 01: Enabled 00 No  4-59