omron — Extended Function Mode

3-7 Parameter List 3 Operation * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-43 Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Page Multi-function output terminal C031 Multi-function output terminal P1 contact selection 00: NO contact at MA; NC contact at MB 01:

NC contact at MA; NO contact at MB 00 No  4-92 C032 Multi-function output terminal P2 contact selection C033 Multi-function output terminal P3 contact selection C034 Multi-function output terminal P4 contact selection C035 Multi-function output terminal P5 contact selection C036 Relay output (MA, MB) contact selection 01 Level and output terminal status C038 Light load signal output mode 00: Enabled during acceleration/deceleration/ constant speed 01: Enabled only during constant speed 01 No  4-101 C039 Light load detection level 0.0 to 2.00 × Rated current Rated current No A C040 Overload warning signal output mode 00: Enabled during acceleration/deceleration/ constant speed 01:

Enabled only during constant speed 01 No  4-49 C041 Overload warning level 0.0: Does not operate. 0.1 × Rated current to 2.00 × Rated current Rated current No A C042 Arrival frequency during acceleration 0.00 to 99.99 100.0 to 400.0 0.00 No Hz 4-94 C043 Arrival frequency during deceleration 0.00 to 99.99 100.0 to 400.0 0.00 No Hz C044 PID deviation excessive level 0.0 to 100.0 3.0 No % 4-31 C045 Arrival frequency during acceleration 2 0.00 to 99.99 100.0 to 400.0 0.00 No Hz 4-94 C046 Arrival frequency during deceleration 2 0.00 to 99.99 100.0 to 400.0 0.00 No Hz C052 PID FB upper limit 0.0 to 100.0 100.0 No % 4-31 C053 PID FB lower limit 0.0 to 100.0 0.0 No %