3-7 Parameter List 3 Operation * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-53 Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Page Options P036 Torque bias mode 00: None 01: Digital Operator 02: Terminal FE 00 No 4-118 4-119 P037 Torque bias value -200. to +200. 0. Yes % P038 Torque bias polarity selection 00: Signed 01: Depends on the RUN direction 00 No P039 Speed limit value in torque control (forward) 0.00 to Maximum frequency 0.00 Yes Hz 4-119 P040 Speed limit value in torque control (reverse) 0.00 to Maximum frequency 0.00 Yes Hz P044 Not used Use "1.00".
*Do not change. 1.00 No s P045 Operation setting at communications error 00: Trip 01: Trip after deceleration stop 02: Ignore 03: Free run 04: Deceleration stop 01 No P046 Output assembly instance No. setting 20 21 100 21 No P047 Input assembly instance No. setting 70 71 101 71 No P048 Operation setting at idle mode detection 00: Trip 01: Trip after deceleration stop 02: Ignore 03: Free run 04:
Deceleration stop 01 No P049 Polarity setting for rotation speed 0/2/4/6/8/10/12/14/16/18/20/22/24/26/28/30/ 32/34/36/38 0 No P055 Pulse train frequency scale 1.0 to 50.0 25.0 No kHz 4-134 P056 Pulse train frequency filter time constant 0.01 to 2.00 0.10 No s P057 Pulse train frequency bias amount -100. to +100. 0. No % P058 Pulse train frequency limit 0. to 100. 100. No %