UNI-T UTD2000 Series — UTD2000 Series User Manual

UTD2000 Series User Manual 57 Model UTD2025CL UTD2052CL UTD2102e UTD2052CEX UTD2072CEX UTD2102CEX Analog Bandwidth 25MHz 50MHz 100MHz 50MHz 70MHz 100MHz Rise Time(Typical) ≤14ns ≤7ns ≤3.5ns ≤7ns ≤5ns ≤3.5ns Channels 2 Analog-to-digital converter (A/D) 8bit Deflection factor range (V/div) 1mV/div~20 V/div(at 1-2-5 increment) Position range ≥±10div Selectable bandwidth limitation (Typical) 20MHz Low frequency response (AC Coupling,-3dB) ≤10 Hz(at BNC) DC gain accuracy (sampling or average sampling mode) 10mV ~20V/div:≤±3% 5mV/div:≤±4% 1mV ~2mV/div:≤±5% DC measurement accuracy (average sampling mode) When vertical position is 0 and N≥16:

± (5%×reading+0.1div+1mV) and selects 1mV /div or 2mV /div; ± (4%×reading+0.1div+1mV) and selects 5mV /div; ± (3%×reading+0.1div+1mV) and selects 10mV /div or 20mV /div; When vertical position is 0 and N≥16: ±(3%×(reading + vertical position reading) + (1%×vertical position reading)]+0.2div) The setting from 5mV/div to 200mV/div plus 2mV; the setting value from 200mV/div to 20V/div plus 50mV Measurement accuracy of voltage difference (△V) (average sampling mode) Under the same setting and environment conditions and after averaging the captured waveforms with a quantity of ≥16, the voltage difference (ΔV) between any two points on the waveform:

± (3%×reading+0.05div) Trigger System Specifications Trigger sensitivity ≤1div Range of trigger level Interior:From the screen center ±5div EXT: ± 3V Trigger level accuracy (Typical) applicable for the signal with rising and falling time ≥20ns Interior:±(0.3div×V/div) (within±4 div from the screen center) EXT:±(6% setting value+40mV) Pre-trigger capacity Normal mode/scan mode, pre-trigger/delay trigger, the pre-trigger depth adjustable Hold-off range 80ns~1.5s Set the level to 50% (Typical) Operate under the condition of input signal frequency of ≥50Hz Edge trigger