5.8 Diagnosing and Resetting Faults ◆ Viewing Fault Trace Data after Fault Troubleshooting 5 ◆ Fault Reset Methods OYMC TOEP C71060622-01-OY V1000 User Manual 223 Step Di splay/Result 1. Turn on the drive input power. The first screen displays. ⇒ 2. 3. Press until the monitor screen is displayed. Press to display the parameter setting screen. ⇒ ⇒ 4. Press and > until U2-02 (Fault History) is displayed. ⇒ 5. Press to view most recent fault (here, oC). ⇒ 6. Press to view drive status information when fault occurred. 7. Parameters U2-03 through U2-17 help determine cause of fault.
⇒ 㨪 㨪 After the Fault Occurs Procedure Fix the cause of the fault, restart the drive, and reset the Press the RESET button on the fault Resetting via Fault Reset Digital Input S4 digital operator Close then open the fault signal digital input via terminal S4. S4 is set fault reset as default (H1-04 = 12) STOP Drive Fault Reset Switch S4 Fault Reset Digital Input SC Digital Input Common If the above methods do not reset the fault, turn off the drive main power supply. Reapply power after LED operator display is out. ON OFF