omron — Motor Does Not Rotate Properly after Pressing RUN Button or After Entering External Run Command

5.9 Troubleshooting without Fault Display 5.9 Troubleshooting without Fault Display This section is for troubleshooting problems that do not trip an alarm or fault. ◆ Cannot Change Parameter Settings ◆ Motor Does Not Rotate Properly after Pressing RUN Button or After Entering External Run Command ■ Motor Does Not Rotate 224 OYMC TOEP C71060622-01-OY V1000 User Manual Cause Possible Solutions The drive is running the motor (i.e., the Run command is present). • Stop the drive and switch over to the Programming Mode. • Most parameters cannot be edited during run. The Access Level is set to restrict access to parameter settings.

• Set the Access Level to allow parameters to be edited (A1-02 = 2). The operator is not in the Parameter Setup Mode (the LED screen will display “PAr”). • See what mode the LED parameter is current set for. • Parameters cannot be edited when in the Setup Mode (“STUP”). Switch modes so that “PAr” appears on the screen. A multi-function contact input terminal is set to allow or restrict parameter editing (H1-01 through H1-06 = 1B). • When the terminal is open, parameters cannot be edited. • Turn on the multi-function contact input set to 1B. The wrong password was entered. • If the password entered to A1-04 does not match the password saved to A1-05, then drive settings cannot be changed.

• Reset the password. • If you cannot remember the password: • Display parameter A1-04. Press the STOP button while pressing at the same time. Parameter A1-05 will appear. • Set a new password to parameter A1-05. Undervoltage was detected. • Check the drive input power voltage by looking at the DC bus voltage • (U1-07). • Check all main circuit wiring. Cause Possible Solutions The drive is not in the Drive Mode. • Check if the DRV light on the LED operator is lit. • Enter the Drive Mode to begin operating the motor. Refer to The Drive and Programming Mode on page 93.