omron — Cooling Fan Replacement

6.4 Drive Cooling Fans 6.4 Drive Cooling Fans NOTICE: Follow cooling fan replacement instructions. The cooling fan cannot operate properly when installed incorrectly and could seriously damage the drive. To ensure maximum useful product life, replace all cooling fans when performing maintenance. Contact your OYMC representative or supplier to order replacement cooling fans as required. Some drive models have multiple cooling fans. For drives with multiple cooling fans, replace all the fans when performing maintenance to ensure maximum useful product life. ◆ Cooling Fan Replacement The cooling fan is installed on the top of the drive.

The cooling fan can easily be replaced without tools or removal of the drive or enclosure parts. WARNING! Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to comply can result in serious personal injury. Before servicing the drive, disconnect all power to the equipment. The internal capacitor remains charged even after the power supply is turned off. The charge indicator LED will extinguish when the DC bus voltage is below 50 Vdc. To prevent electric shock, wait at least five minutes after all indicators are OFF and measure the DC bus voltage level to confirm safe level. CAUTION! Burn Hazard. Do not touch a hot drive heatsink.

Failure to comply could result in minor or moderate injury. Shut off the power to the drive when replacing the cooling fan. To prevent burns, wait at least 15 minutes and ensure the heatsink has cooled down. 250 OYMC TOEP C71060622-01-OY V1000 User Manual