omron — Connecting a Noise Filter

7.4 Installing Peripheral Devices ◆ Connecting a Surge Protector A surge protector suppresses surge voltage generated from switching an inductive load near the drive. Inductive loads include magnetic contactors, relays, valves, solenoids and brakes. Always use a surge protector or diode when operating with an inductive load. Note: Never connect a surge protector to the drive output. ◆ Connecting a Noise Filter ■ Input-Side Noise Filter Drive outputs generate noise as a result of high-speed switching. This noise flows from inside the drive back toward the power supply, possible affecting other equipment.

Installing a noise filter to the input side of the drive can reduce the amount of noise flowing back into the power supply. This also prevents noise from entering the drive from the power supply. • Use a noise filter specifically designed for AC drives. • Install the noise filter as close as possible to the drive. Figure 7.5 B C A MCCB MCCB D A – Power supply C – Drive B – Input-side noise filter D – Other control device Figure 7.5 Input-Side Noise Filter (Single-Phase 200 V) 268 OYMC TOEP C71060622-01-OY V1000 User Manual 1 3 S/L2 2 4 E