omron — A.4 Drive Specifications

A.4 Drive Specifications 286 OYMC TOEP C71060622-01-OY V1000 User Manual Item Specification Control Characteristics Functions Momentary Power Loss Ride-Thru, Speed Search, Over /Undertorque detection, Torque Limit, Multi-Step Speed (17 steps max), Accel/Decel Time Switch, S-Curve Accel/Decel, 3-Wire Sequence, Rotational Auto- Tuning, Stationary Auto-Tuning of Line-to-Line Resistance, Dwell, Cooling Fan ON/OFF, Slip Compensation, Torque Compensation, Frequency Jump, Frequency Reference Upper/Lower Limit, DC Injection Braking (start and stop), High Slip Braking, PID Control (with Slip Function), Energy Saving, MEMOBUS (RS-485/422 Max 115.2 kbps), Fault Reset, Parameter Copy.

Protection Functions Motor Protection Momentary Motor overheat protection via output current sensor Overcurrent Protection Drives stops when output exceeds 200% of the rated current (Heavy Duty) Overload Protection A stop command will be entered after operating at 150% for 60 s (Heavy Duty) Low Voltage Protection Drive stops when DC bus voltage falls below the levels indicated: 190 V (3-phase 200 V), 160 V (single-phase 200 V), 380 V (3-phase 400 V), 350 V (3-phase 380 V) Momentary Power Loss Ride-Thru 3 selections available: Ridethru disabled (stops after 15 ms), time base of 0.5 s, and continue running until power is restored.

Heatsink Overheat Protection Protected by thermistor Braking Resistor Overheat Protection Overheat sensor for braking resistor (Optional ERF-type, 3%ED) Stall Prevention Stall prevention is available during acceleration, deceleration, and during run. Separate settings for each type of stall prevention determine the current level at which stall prevention is triggered.

Cooling Fan Failure Protection Circuit protection (“fan-lock” sensor) Ground Protection Electronic circuit protection (triggered by the same levels as momentary current protection) DC Bus Charge LED Remains lit until DC bus voltage falls below 50 V Environment Storage/Installation Area Indoors Ambient Temperature -10 to +40 °C (wall-mounted enclosure) -10 to +50 °C (open chassis) Humidity 95 RH% or less with no condensation Storage Temperature -20 to +60 °C allowed for short-term transport of the product Altitude 1000 m or less Shock, Impact 10 to 20 Hz: 9.8 m/S 2 20 to 55 Hz: 5.9 m/S 2