B.2 Parameter Table 312 OYMC TOEP C71060622-01-OY V1000 User Manual No. Name Description Range Def. Control Mode Addr. Hex Pg. V/f O LV P M d4-05 Frequency Reference Bias Operation Mode Selection (Up/Down 2) 0: Holds the bias value when Up/Down 2 reference is on or off. 1: When the Up 2 reference and Down 2 reference are both on or both off, the applied bias becomes 0. Currently selected accel/ decel. times are used. Enabled only when d4-03 = 0. 0,1 0 A A A 2AC — d4-06 Frequency Reference Bias (Up/Down 2) The Up/Down 2 bias value is saved in d4-06 once the frequency reference is adjusted. It is limited by d4-08 and d4-09.
The bias can be set by the user, but will be disabled under the following conditions: • When none of the digital inputs are assigned to Up2/Down2 commands. • When the frequency reference source has been changed (including multi-step speed). • When both d4-03 = 0 and d4-05 = 1 and the Up 2 / Down 2 commands are both on or both off. • When the max output frequency E1-04 has changed. • When the digital frequency reference has changed.
-99.9 to +100.0 0.0% A A A 2AD — d4-07 Analog Frequency Reference Fluctuation Limit (Up/Down 2) When during Up2/Down2 the frequency reference value from analog or pulse input changes for more than the level set in d4-07, the bias value is hold and the reference is changed to the new value. After the speed reaches the frequency reference the bias hold is released. (Works with frequency reference from analog or pulse input only) 0.1 to +100.0 1.0% A A A 2AE — d4-08 Frequency Reference Bias Upper Limit (Up/Down 2) Sets the upper limit for d4-06 in percent of the maximum output frequency E1-04.
0.1 to 100.0 0.0% A A A 2AF — d4-09 Frequency Reference Bias Lower Limit (Up/Down 2) Sets the lower limit for d4-06 in percent of the maximum output frequency E1-04. -99.9 to 0.0 0.0% A A A 2B0 —