B.2 Parameter Table OYMC TOEP C71060622-01-OY V1000 User Manual 319 No. Name Description Range Def. Control Mode Addr. Hex Pg. V/f OL V PM E5: PM Motor Parameters E5-01 Motor Code Selection (for PM motor) Enter the Yaskawa motor code for the PM motor being used. Various motor parameters are automatically set based on the value of this parameter. Note: Set to FFFF when using a specialized or custom motor. For all other motors: 0 0 0 0 Motor voltage class and capacity 0: Pico motor 0: 1800 r/min (SMRA series) series 1: Derated torque 1: 3600 r/min IPM motor series (SSR1 series) 2: 1750 r/min 2: Constant torque series IPM motor 3: 1450 r/min (SST4 series) series 4: 1150 r/min series F:
Custom motor All motor parameters are re-initialized to factory settings when this parameter is set. 0000 to FFFF − − S 329 379 E5-02 Motor Rated Capacity (for PM motor) Sets the rated capacity of the motor. 0.10 to 18.5 − − S 32A 382 E5-03 Motor Rated Current Sets the motor rated current in amps. 10 to 200% of drive rated current − − S 32B 382 B E5-04 Motor Poles Sets the number of motor poles. 2 to 48 − − S 32C 382 E5-05 Motor Resistance Set the resistance for each motor phase in units of 0.001 Ω. 0.000 to 65.000 − − S 32D 382 E5-06 Motor d Axis Inductance Sets the d axis inductance in units of 0.01 mH. 0.00 to 300.00 − − S 32E 382