B.2 Parameter Table Default setting value is dependent on parameter A1-02, Control Method Selection. The value shown is for A1-02 = 2-OLV control. Default setting value is dependent on parameter A1-02, Control Method Selection. The value shown is for A1-02 = 0-V/f Control. Default setting value is dependent on parameter A1-06. This setting value is 0 when A1-06 = 0, and 1 when A1-06 does not = 0. Default setting value is dependent on parameter E5-01, Motor Code Selection. Default setting value is dependent on parameter o2-04, Drive Unit Selection. Default setting value is dependent on parameter o2-04, Drive Capacity, when parameter H1- †† = 16 Motor 2 is selected as a digital input.

The value shown is when o2-04 = 98 (62H) 200 V class 0.4 kW drive. Range upper limit is dependent on parameters E5-01, Motor Code Selection, and A1-02, Control Method Selection. The value shown is for A1-02 = 5-PM OLV control. Range upper limit is dependent on parameter E4-01 Motor 2 Rated Current. Parameter can be changed during run. Values shown here are for 200 V class drives. Double the value when using a 400 V class drive. Parameter setting value is not reset to the default value during drive initialization, A1-03 = 1110, 2220, 3330. Parameter ignored when E1-11, Motor 1 Mid Output Frequency 2, and E1-12, Motor 1 Mid Output Frequency Voltage 2, are set to 0.0.

Setting units for this parameter are determined by o2-04, Drive Unit Selection. Less than 11 kW: 2 decimal points, 11 kW and above: 1 decimal point. When parameter A1-02 = 5-PM OLV Control, E3-13 Motor 2 Base Voltage will be equal to T1-03, Motor Rated Voltage, after Auto-Tuning the drive Default setting is determined by the V/f pattern selected to parameter E1-03. Default setting changes when using OLV Control for PM motors. Setting range becomes 0.00 to 130.00 for drives 0.2 kW and smaller. 320 OYMC TOEP C71060622-01-OY V1000 User Manual No. Name Description Range Def. Control Mode Addr. Hex Pg. V/f OL V PM E5-07 Motor q Axis Inductance Sets the q axis inductance in units of 0.01 mH.

0.00 to 600.00 − − S 32F 382 E5-09 Motor Induction Voltage Constant 1 Set the induced phase peak voltage in units of 0.1 mV (rad/s) [electrical angle]. Set this parameter when using a Yaskawa SSR1 series PM motor with derate torque, or a Yaskawa SST4 series motor with constant torque. When setting this parameter, E5-24 should be set to 0. An alarm will be triggered if both E5- 09 and E5-24 are set to 0, or if neither parameter is set to 0. 0.0 to 2000.0 − − S 331 382 E5-24 Motor Induction Voltage Constant 2 Set the induced phase-to-phase rms voltage in units of 0.1 mV/(r/min) [mechanical angle]. Set this parameter when using a Yaskawa SMRA series pico motor.

When setting this parameter, E5-09 should be set to 0. An alarm will be triggered if both E5- 09 and E5-24 are set to 0, or if neither parameter is set to 0. If E5-03 (Motor Rated Current) is set to 0, however, then an alarm will not be triggered when both E5-09 and E5-24 are set to 0. 0.0 to 2000.0 0 − − S 353 382