B.2 Parameter Table ◆ Parameters that Change with the Motor Code Selection The following tables show parameters and default settings that change with the motor code selection E5-01 when Open Loop Vector for PM motors is used. ■ Yaskawa Pico Motor (SPM motor) Table B.8 1800 rpm Type Yaskawa Pico Motor Settings 382 OYMC TOEP C71060622-01-OY V1000 User Manual Par.
Description Unit Default Settings E5-01 Motor Code − 0002 0003 0005 0006 0008 Voltage class Rated power − 200 Vac 0.4 kW 200 Vac 0.75 kW 200 Vac 1.5 kW 200 Vac 2.2 kW 200 Vac 3.7 kW Rated speed min-1 1800 1800 1800 1800 1800 E5-02 Motor rated power kW 0.4 0.75 1.5 2.2 3.7 E5-03 Motor rated current A 2.1 4.0 6.9 10.8 17.4 E5-04 Motor pole number – 8 8 8 8 8 E5-05 Motor winding resistance W 2.47 1.02 0.679 0.291 0.169 E5-06 d-axis inductance mH 12.7 4.8 3.9 3.6 2.5 E5-07 q-axis inductance mH 12.7 4.8 3.9 3.6 2.5 E5-09 Induction voltage constant 1 mVsec/rad 0 0 0 0 0 E5-24 Induction voltage constant 2 mV/min-1 62.0 64.1 73.4 69.6 72.2 E1-04 Maximum output frequency Hz 120 120 120 120 120 E1-05 Maximum output voltage V 200.0 200.0 200.0 200.0 200.0 E1-06 Base voltage Hz 120 120 120 120 120 E1-09 Minimum output frequency Hz 6 6 6 6 6 L3-24 Motor acceleration time s 0.064 0.066 0.049 0.051 0.044 n8-49 Pull-in current % 0 0 0 0 0